3
3.3.3 Over Load Protection
When the total load exceed 130%󱲯160% of the maximum output current, the power
supply shall be latched into the state of shutdow
3.4 Physical Environment
Operation Conditions
The power supply shall be capable of continuous operation and meet all electrical
specification without need for adjustment when subjected to the following environ-
mental conditions:
Temp. Vs Load Condition
Humidity
Operation
Storage
-20C 󱲯80C
10% 󱲯90%RH
5% 󱲯90%RH
0 󱲯30C@Full Load
-20C 󱲯80C@90% Rated Load
-20C 󱲯80C@80% Rated Load
3.3.4 3-Band Thermal Management System
H(High):use by maximum system utilization,cooling down effectively.
A(Auto):PSU regulates fan speed automatically.(Recommended)
L(Low):use by low system utilization,like stand-by mode,etc.When
temperature increases fast,PSU switches automatically to Level A(Auto).